0000305: There is no TP of band2,1X.

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000305 [DZB] 0.unknown/unspecified major always 23-11-10 10:19 25-11-10 13:33
Reporter Yuan Tang View Status public  
Assigned To Harm-Jan Stiepel
Priority normal Resolution open  
Status resolved  
Summary 0000305: There is no TP of band2,1X.
Description There is no TP of band2,1X.
  (The convertor of band2,1X had been replaced in the IVC yesterday. So it
   is the problem from another unit of the DZB. Harm-Jan: could we try to locate
   and solve this problem on Thursday?)
Additional Information 20101125:
The problem of the TP of band2,1X has been solved this morning after Harm-Jan
replaced the LO module and the Filter module in the IVC.
nr subbands 1
nr polarisations
nr channels
bandwidth
multi-subarray no
recirculation no
Attached Files

- Relationships

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
23-11-10 10:19 Yuan Tang New Issue
23-11-10 10:19 Yuan Tang nr subbands  => 1
23-11-10 10:19 Yuan Tang multi-subarray  => no
23-11-10 10:19 Yuan Tang recirculation  => no
23-11-10 10:19 Yuan Tang Assigned To  => Harm-Jan Stiepel
23-11-10 10:19 Yuan Tang Status new => assigned
25-11-10 13:33 Yuan Tang Status assigned => resolved
25-11-10 13:33 Yuan Tang Additional Information Updated