0000241: RTD. Pointing offset error in Declination.

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000241 [RT] pointing major always 23-02-10 09:36 16-03-10 09:24
Reporter Hans van Someren Greve View Status public  
Assigned To Hans van Someren Greve
Priority high Resolution open  
Status closed  
Summary 0000241: RTD. Pointing offset error in Declination.
Description In pointing observations RTD shows an offset error of order > -20 millidegr.
Additional Information
RT D
Attached Files

- Relationships

- Notes
(0000266)
Peter Gruppen
23-02-10 14:52

de aftand tussen de vork is opgemeten was iets te groot 20.2 mm en de encoder opnieuw afgesteld op 20.0 mm verder zag alles er goed uit er zat geen water in de encoder enz. dus het probleem verder zoeken.
 
(0000268)
Hans van Someren Greve
26-02-10 11:50

The offset has been measured, and has been applied on 25-02-2010 15:00 UT
 

- Issue History
Date Modified Username Field Change
23-02-10 09:36 Hans van Someren Greve New Issue
23-02-10 09:36 Hans van Someren Greve RT  => D
23-02-10 14:52 Peter Gruppen Note Added: 0000266
23-02-10 14:52 Peter Gruppen Assigned To  => Hans van Someren Greve
23-02-10 14:52 Peter Gruppen Status new => assigned
26-02-10 11:50 Hans van Someren Greve Note Added: 0000268
26-02-10 11:50 Hans van Someren Greve Status assigned => progressing
16-03-10 09:24 Hans van Someren Greve Status progressing => closed