0000240: RTA. Problem execution of pointing pattern.

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000240 [RT] pointing minor always 23-02-10 09:32 24-02-10 16:24
Reporter Hans van Someren Greve View Status public  
Assigned To Peter Gruppen
Priority normal Resolution fixed  
Status resolved  
Summary 0000240: RTA. Problem execution of pointing pattern.
Description When executing a pointing observation, RTA is not able to reach the new position within 10 seconds.
Additional Information RTa has no problem during an observation in which a position is tracked continuously.
RT 9
Attached Files

- Relationships

- Notes
(0000267)
Jan Pieter de Reijer
24-02-10 16:24

dec proximity switch replaced
Also at Dec RTA.
problem solved, (acc. HvSG)
 

- Issue History
Date Modified Username Field Change
23-02-10 09:32 Hans van Someren Greve New Issue
23-02-10 09:32 Hans van Someren Greve RT  => 9
23-02-10 12:49 Peter Gruppen Assigned To  => Peter Gruppen
23-02-10 12:49 Peter Gruppen Status new => testing
23-02-10 15:56 Hans van Someren Greve Summary RT9. Problem execution of pointing pattern. => RTA. Problem execution of pointing pattern.
23-02-10 15:56 Hans van Someren Greve Description Updated
23-02-10 15:57 Hans van Someren Greve Additional Information Updated
24-02-10 16:24 Jan Pieter de Reijer Status testing => resolved
24-02-10 16:24 Jan Pieter de Reijer Resolution open => fixed
24-02-10 16:24 Jan Pieter de Reijer Note Added: 0000267