Notes |
(0000398)
Yuan Tang
21-11-12 12:12
|
The unstable TP of Band2,1X is still there after replacing
the convertor of Band2,1X in the IVC. |
|
(0000399)
Juergen Morawietz
21-11-12 13:26
|
21.11.2012: replaced IVC converter unit.
Did not solve the problem regarding last Observer Report.
- Juergen - |
|
(0000400)
Juergen Morawietz
28-11-12 13:29
|
27.11.2012: replaced IVC filter unit.
But regarding Observer Report from 28.11. there is no TP at all now.
- Juergen - |
|
(0000409)
Juergen Morawietz
08-01-13 17:01
|
8.1.2013
no complains anymore
Status: "closed"
- Juergen - |
|