Anonymous | Login | 23-11-2024 15:57 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000077 | [DZB] 0.unknown/unspecified | major | have not tried | 22-09-08 11:24 | 20-07-11 12:28 | ||||
Reporter | Yuan Tang | View Status | public | ||||||
Assigned To | Hans Weggemans | ||||||||
Priority | normal | Resolution | open | ||||||
Status | closed | ||||||||
Summary | 0000077: Band7 the TP of 3X is unstable. | ||||||||
Description | 10-20% of TP, see 10804592,10804602. | ||||||||
Additional Information |
07/10,2008 The whole unit of band7 in the IVC has been swapped with band6(filter,convertor, LO unit). 20110720: item set to 'closed' |
||||||||
nr subbands | 1 | ||||||||
nr polarisations | 1 | ||||||||
nr channels | |||||||||
bandwidth | |||||||||
multi-subarray | no | ||||||||
recirculation | no | ||||||||
Attached Files | |||||||||
|
Notes | |
(0000099) Bert Woestenburg 24-10-08 09:57 |
The problem has not been seen since 7-10-2008. Item considered to be resolved. |