0000058: RT3: Mechanical Decl. switch remained in 'maak-positie'

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000058 [RT] pointing minor N/A 18-08-08 08:14 18-08-08 08:23
Reporter Jurjen Sluman View Status public  
Assigned To Jan Pieter de Reijer
Priority normal Resolution fixed  
Status resolved  
Summary 0000058: RT3: Mechanical Decl. switch remained in 'maak-positie'
Description On monday morning 18-aug-2008 the RT had a fixed position of:
G+60 (ha) / G +50 (dec).
Additional Information
RT 3
Attached Files

- Relationships
related to 0000059resolved Jan Pieter de Reijer RT3 (Decl): install a new position switch head with bearing 

- Notes
(0000058)
Jurjen Sluman
18-08-08 08:16

After release of the Decl. switch it is possible to observe again
 
(0000059)
Jurjen Sluman
18-08-08 08:19

Remark of Jan Pieter de Reijer:
a new head with bearing should be installed.
 

- Issue History
Date Modified Username Field Change
18-08-08 08:14 Jurjen Sluman New Issue
18-08-08 08:14 Jurjen Sluman RT  => 3
18-08-08 08:16 Jurjen Sluman Note Added: 0000058
18-08-08 08:16 Jurjen Sluman Assigned To  => Jan Pieter de Reijer
18-08-08 08:16 Jurjen Sluman Status new => assigned
18-08-08 08:19 Jurjen Sluman Note Added: 0000059
18-08-08 08:22 Jurjen Sluman Relationship added related to 0000059
18-08-08 08:23 Jurjen Sluman Status assigned => resolved
18-08-08 08:23 Jurjen Sluman Resolution open => fixed