Anonymous | Login | 25-11-2024 00:11 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000050 | [RT] cabling | major | N/A | 06-08-08 08:15 | 24-11-08 11:35 | ||||
Reporter | Bert Woestenburg | View Status | public | ||||||
Assigned To | Harm-Jan Stiepel | ||||||||
Priority | normal | Resolution | open | ||||||
Status | resolved | ||||||||
Summary | 0000050: Repair spare coax cables on telescope 9 | ||||||||
Description | Telescope 9 does not have useable spare coax cables anymore. Repair of the spare cables is necessary. Find out the cause of failure (short, broken, water inside cable?) and repair based on findings. | ||||||||
Additional Information | Problem has been discovered by Harm-Jan during solving LO-problem in telescope 9 (see error report 0000044) | ||||||||
RT | 9 | ||||||||
Attached Files | |||||||||
|