Anonymous | Login | 21-11-2024 20:06 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000427 | [IVC/ADC] 0.unknown/unspecified | major | sometimes | 06-09-13 07:53 | 30-01-14 15:52 | ||||
Reporter | Yuan Tang | View Status | public | ||||||
Assigned To | Juergen Morawietz | ||||||||
Priority | normal | Resolution | reopened | ||||||
Status | closed | ||||||||
Summary | 0000427: The RTC is not stable. | ||||||||
Description | The RTC is not stable, sometimes no data, the problem may come from the LO-box of RTC in the IVC. | ||||||||
Additional Information |
Reopened, maybe this is connected with the following sometimes no signal RTC due to lantronics mss 485 LO steering unit problem (mostly ok after manual power supply interrupt) |
||||||||
RT | C | ||||||||
sub-band | 0, 1, 2, 3, 4, 5, 6, 7 | ||||||||
polarisation | X, Y | ||||||||
Attached Files | |||||||||
|
Notes | |
(0000425) Juergen Morawietz 02-12-13 08:21 |
an old one. Seems to be fixed. -> closed |
(0000426) Juergen Morawietz 30-01-14 15:52 |
No evidence that the MSS485 caused this problem. RTC now okay. |