0000405: The bad serial link problem

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000405 [DZB] 0.unknown/unspecified major random 31-05-12 10:32 12-07-12 07:31
Reporter Yuan Tang View Status public  
Assigned To Sjouke Zwier
Priority normal Resolution open  
Status resolved  
Summary 0000405: The bad serial link problem
Description There was the DZB problem which happened at UT18:17 with error message of
   bad IVC band. The system works again after rebooting the DZB. But after that
   The bad serial link (of DDU presel board2,module 0) problem happened 4 times.
   It seems to me it is something new after Tuesday maintenance.
Additional Information The bad serial link error (of DDU presel board2,module 0)were probalbly caused by overheating.
Because there were 3 fans in the lower fan tray unit just below this board who were not turning.
I have replaced the complete Fan-tray unit.
nr subbands 1
nr polarisations
nr channels
bandwidth
multi-subarray no
recirculation no
Attached Files

- Relationships

- Notes
(0000388)
Sjouke Zwier
12-07-12 07:31

Because there were 3 fans in the lower fan tray unit just below this board who were not turning.
I have replaced the complete Fan-tray unit.
 

- Issue History
Date Modified Username Field Change
31-05-12 10:32 Yuan Tang New Issue
31-05-12 10:32 Yuan Tang nr subbands  => 1
31-05-12 10:32 Yuan Tang multi-subarray  => no
31-05-12 10:32 Yuan Tang recirculation  => no
31-05-12 10:32 Yuan Tang Assigned To  => Sjouke Zwier
31-05-12 10:32 Yuan Tang Status new => assigned
12-07-12 07:05 Sjouke Zwier Status assigned => progressing
12-07-12 07:31 Sjouke Zwier Note Added: 0000388
12-07-12 07:31 Sjouke Zwier Status progressing => resolved
12-07-12 07:31 Sjouke Zwier Additional Information Updated