Anonymous | Login | 21-11-2024 14:57 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000405 | [DZB] 0.unknown/unspecified | major | random | 31-05-12 10:32 | 12-07-12 07:31 | ||||
Reporter | Yuan Tang | View Status | public | ||||||
Assigned To | Sjouke Zwier | ||||||||
Priority | normal | Resolution | open | ||||||
Status | resolved | ||||||||
Summary | 0000405: The bad serial link problem | ||||||||
Description |
There was the DZB problem which happened at UT18:17 with error message of bad IVC band. The system works again after rebooting the DZB. But after that The bad serial link (of DDU presel board2,module 0) problem happened 4 times. It seems to me it is something new after Tuesday maintenance. |
||||||||
Additional Information |
The bad serial link error (of DDU presel board2,module 0)were probalbly caused by overheating. Because there were 3 fans in the lower fan tray unit just below this board who were not turning. I have replaced the complete Fan-tray unit. |
||||||||
nr subbands | 1 | ||||||||
nr polarisations | |||||||||
nr channels | |||||||||
bandwidth | |||||||||
multi-subarray | no | ||||||||
recirculation | no | ||||||||
Attached Files | |||||||||
|
Notes | |
(0000388) Sjouke Zwier 12-07-12 07:31 |
Because there were 3 fans in the lower fan tray unit just below this board who were not turning. I have replaced the complete Fan-tray unit. |