| 0000405 | [DZB] 0.unknown/unspecified | major | random | 31-05-12 10:32 | 12-07-12 07:31 | ||||
| Reporter | Yuan Tang | View Status | public | ||||||
| Assigned To | Sjouke Zwier | ||||||||
| Priority | normal | Resolution | open | ||||||
| Status | resolved | ||||||||
| Summary | 0000405: The bad serial link problem | ||||||||
| Description |
There was the DZB problem which happened at UT18:17 with error message of bad IVC band. The system works again after rebooting the DZB. But after that The bad serial link (of DDU presel board2,module 0) problem happened 4 times. It seems to me it is something new after Tuesday maintenance. |
||||||||
| Additional Information |
The bad serial link error (of DDU presel board2,module 0)were probalbly caused by overheating. Because there were 3 fans in the lower fan tray unit just below this board who were not turning. I have replaced the complete Fan-tray unit. |
||||||||
| nr subbands | 1 | ||||||||
| nr polarisations | |||||||||
| nr channels | |||||||||
| bandwidth | |||||||||
| multi-subarray | no | ||||||||
| recirculation | no | ||||||||
| Attached Files | |||||||||
|
|
|||||||||
Notes |
|
|
(0000388) Sjouke Zwier 12-07-12 07:31 |
Because there were 3 fans in the lower fan tray unit just below this board who were not turning. I have replaced the complete Fan-tray unit. |