0000352: There is the problem on the correlator of COR03.

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000352 [DZB] correlator board major always 23-05-11 10:24 24-05-11 13:28
Reporter Yuan Tang View Status public  
Assigned To Sjouke Zwier
Priority normal Resolution open  
Status resolved  
Summary 0000352: There is the problem on the correlator of COR03.
Description There was the problem of the correlator during the weekend, which started at
  UT20:06,21/05 and the problem is on the COR03(It seems to me the problem
  come from the power supply of COR03).
  Now Sjouke is working on it in the WSRT.
Additional Information The problem on the correlator board of the DZB had been solved yesterday after
replacing the defect 5V power supply and reset the correlator.
nr subbands 1
nr polarisations
nr channels
bandwidth
multi-subarray no
recirculation no
Attached Files

- Relationships

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
23-05-11 10:24 Yuan Tang New Issue
23-05-11 10:24 Yuan Tang nr subbands  => 1
23-05-11 10:24 Yuan Tang multi-subarray  => no
23-05-11 10:24 Yuan Tang recirculation  => no
23-05-11 10:24 Yuan Tang Assigned To  => Sjouke Zwier
23-05-11 10:24 Yuan Tang Status new => assigned
24-05-11 13:28 Yuan Tang Status assigned => resolved
24-05-11 13:28 Yuan Tang Additional Information Updated