Summary | 0000296: RT7 often no correlated signal. Probably a bad LO cable. | |||||||||||
Description |
The correlated signal of RT7 sometimes drops out. This is mostly seen after start of a new measurement in the -90 - -60 HA range. The signal does not come back by itself during the measurement. Harm Jan has already noticed a wrong LO status during such an event. |
|||||||||||
Additional Information |
20101012 RT7 problem It happened quite often that the cross correlations of 7X*X,7Y*Y have no Ampls after the observation started from HA -90 deg. It might be caused by a bad HA jumper cable for the LO in RT7. 20101015 On RT7 the problem of bad connection of the LO cable around HA-90 deg has been solved after changing the LO cable yesterday. |
|||||||||||