0000206: Ax total power drop at HA -90

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000206 [RT] cabling minor sometimes 06-01-10 11:16 15-02-10 10:48
Reporter Geert Kuper View Status public  
Assigned To Harm-Jan Stiepel
Priority normal Resolution fixed  
Status resolved  
Summary 0000206: Ax total power drop at HA -90
Description A short total power drop in Ax is often seen at the beginning of a 12hrs
observation.
Additional Information De kabel tussen FE box en tel. aansluitkast is vervangen door een andere kleur.
Na test niet weer opgetreden.
RT A
Attached Files

- Relationships

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
06-01-10 11:16 Geert Kuper New Issue
06-01-10 11:16 Geert Kuper RT  => A
06-01-10 11:17 Geert Kuper Assigned To  => Harm-Jan Stiepel
06-01-10 11:17 Geert Kuper Status new => assigned
15-02-10 10:48 Harm-Jan Stiepel Status assigned => resolved
15-02-10 10:48 Harm-Jan Stiepel Resolution open => fixed
15-02-10 10:48 Harm-Jan Stiepel Additional Information Updated