0000177: Bad sample device AX in ADC2

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000177 [IVC/ADC] 0.unknown/unspecified minor always 16-10-09 08:00 31-05-13 08:22
Reporter Jurjen Sluman View Status public  
Assigned To Hans Weggemans
Priority normal Resolution fixed  
Status closed  
Summary 0000177: Bad sample device AX in ADC2
Description after testing by Hans Weggemans
Additional Information
RT A
sub-band 2
polarisation X
Attached Files

- Relationships

- Notes
(0000192)
Hans Weggemans
19-10-09 05:16

sampler unit van AXB2 vervangen op ADC board
 

- Issue History
Date Modified Username Field Change
16-10-09 08:00 Jurjen Sluman New Issue
16-10-09 08:00 Jurjen Sluman RT  => A
16-10-09 08:00 Jurjen Sluman sub-band  => 2, 3
16-10-09 08:00 Jurjen Sluman polarisation  => X
16-10-09 08:01 Jurjen Sluman Assigned To  => Hans Weggemans
16-10-09 08:01 Jurjen Sluman Status new => assigned
16-10-09 08:01 Jurjen Sluman sub-band 2, 3 => 2
19-10-09 05:16 Hans Weggemans Note Added: 0000192
19-10-09 05:16 Hans Weggemans Status assigned => resolved
19-10-09 05:16 Hans Weggemans Description Updated
31-05-13 08:22 Juergen Morawietz Status resolved => closed
31-05-13 08:22 Juergen Morawietz Resolution open => fixed