Anonymous | Login | 22-11-2024 13:25 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000079 | [MFFE] phase switching | major | always | 19-10-08 16:36 | 19-02-09 07:54 | ||||
Reporter | Yuan Tang | View Status | public | ||||||
Assigned To | Hans van der Marel | ||||||||
Priority | normal | Resolution | fixed | ||||||
Status | resolved | ||||||||
Summary | 0000079: The noise source step of 4Y(MFFE-16) is too low(Lband). | ||||||||
Description | Maybe we can check if it happens only with FE phase switch mode. | ||||||||
Additional Information |
Hallo waarnemer en Harm-Jan, Ik heb zojuist met Albert Bos gesproken over het probleem van de ruisbronstap op 92 cm in 6Y. Het blijkt dat het faseschakelpatroon van 6Y niet symmetrisch is als de ruisbron aan is. Het is zelfs zo dat bij nadere bestudering van het faseschakelpatroon er nog meer telescopen zijn waar het niet goed is (o.a. 7Y, 5Y en 4Y). Albert gaat nu na wat er veranderd kan zijn en na de VLBI zal hij aan een oplossing gaan werken. Groeten, Hans |
||||||||
MFFE | 16 | ||||||||
RT | 4 | ||||||||
MFFE-band | L-band | ||||||||
polarisation | Y | ||||||||
sky frequency (MHz) | |||||||||
Attached Files | |||||||||
|
Notes | |
(0000116) Yuan Tang 11-12-08 14:25 |
20081211: The problem has been solved after using the new version of DZB. |