Anonymous | Login | 22-11-2024 07:42 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000071 | [RT] pointing | major | sometimes | 12-09-08 11:32 | 22-09-08 12:51 | ||||
Reporter | Geert Kuper | View Status | public | ||||||
Assigned To | Jan Pieter de Reijer | ||||||||
Priority | normal | Resolution | open | ||||||
Status | resolved | ||||||||
Summary | 0000071: Declination limit switch stuck | ||||||||
Description |
Friday September 12 the telescope stopped because the declination limit switch was stuck. |
||||||||
Additional Information |
Harm Jan Stiepel moved the switch several times to make it loose and after that the problem was over. May be someone can check this switch. Problem has been understood and solved by replacement of switch. |
||||||||
RT | 3 | ||||||||
Attached Files | |||||||||
|
Notes | |
(0000085) Yuan Tang 16-09-08 08:49 |
The RT3 was stuck again at 15/09(Monday). After checking the 18 degree switch has been replaced and the problem has been solved. |