0000071: Declination limit switch stuck

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000071 [RT] pointing major sometimes 12-09-08 11:32 22-09-08 12:51
Reporter Geert Kuper View Status public  
Assigned To Jan Pieter de Reijer
Priority normal Resolution open  
Status resolved  
Summary 0000071: Declination limit switch stuck
Description Friday September 12 the telescope stopped because the declination limit switch was stuck.
Additional Information Harm Jan Stiepel moved the switch several times to make it loose and after that the problem was over.
May be someone can check this switch.
Problem has been understood and solved by replacement of switch.
RT 3
Attached Files

- Relationships

- Notes
(0000085)
Yuan Tang
16-09-08 08:49

The RT3 was stuck again at 15/09(Monday). After checking the 18 degree
switch has been replaced and the problem has been solved.
 

- Issue History
Date Modified Username Field Change
12-09-08 11:32 Geert Kuper New Issue
12-09-08 11:32 Geert Kuper RT  => 3
12-09-08 11:32 Geert Kuper Assigned To  => Jan Pieter de Reijer
12-09-08 11:32 Geert Kuper Status new => assigned
16-09-08 08:49 Yuan Tang Note Added: 0000085
16-09-08 08:58 Yuan Tang Status assigned => resolved
22-09-08 12:51 Bert Woestenburg Additional Information Updated