Anonymous | Login | 25-11-2024 00:32 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000068 | [submission] 0.unknown/unspecified | minor | always | 08-09-08 08:10 | 04-11-08 12:34 | ||||
Reporter | Jurjen Sluman | View Status | public | ||||||
Assigned To | Hans van der Marel | ||||||||
Priority | normal | Resolution | open | ||||||
Status | closed | ||||||||
Summary | 0000068: Baseline based error RT1-2 | ||||||||
Description |
Tom Oosterloo has noticed that already since a while, for a 20-Mhz line observation, the data on baseline RT1-2 (both XX and YY) are systematically too large by a few %. Checking the calibration etc, Tom comes to the conclusion that there is a baseline based error on this baseline. Attached is a plot of data of 3C295 of amplitude vs uvdistance to illustrate. You can spot the outliers around 23 Jy, being baseline RT1-2 |
||||||||
Additional Information | |||||||||
Attached Files | c1-2.pdf [^] (282,870 bytes) 08-09-08 08:14 | ||||||||
|