Anonymous | Login | 10-11-2024 00:03 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000389 | [DZB] 0.unknown/unspecified | major | always | 19-12-11 14:06 | 18-01-12 12:35 | ||||
Reporter | Yuan Tang | View Status | public | ||||||
Assigned To | Juergen Morawietz | ||||||||
Priority | normal | Resolution | open | ||||||
Status | closed | ||||||||
Summary | 0000389: In band5 the DY has no TP and *YDY have no ampls. | ||||||||
Description | In band5 the DY has no TP and *YDY have no ampls. | ||||||||
Additional Information |
Issue closed on 18.01.2012 - Juergen - |
||||||||
nr subbands | 1 | ||||||||
nr polarisations | |||||||||
nr channels | |||||||||
bandwidth | |||||||||
multi-subarray | no | ||||||||
recirculation | no | ||||||||
Attached Files | |||||||||
|
Notes | |
(0000369) Juergen Morawietz 20-12-11 14:08 |
Diagnostics: TP at IVC converter monitoring output is okay. frequency at testpoint ADC/sampler = 0Hz! Checked input power at ADC unit: is okay => sampler unit is defective. Changed sampler unit on ADC board; now freq is Note: 0000800kHz changed status to "Testing" Juergen (20.12.2011) |