Notes |
(0000365)
Juergen Morawietz
21-10-11 08:40
|
Juergen M., nov. 21th 2011:
Action in accordance with Jurjen en Geert postponed to end of VLBI.
Reason: VLBI does not suffer from this issue and replacement of units would
require recalibration of the now well working system.
-- |
|
(0000366)
Juergen Morawietz
21-10-11 08:41
|
eh, previous note is from oct.(!) 21th 2011
-- |
|
(0000367)
Juergen Morawietz
15-11-11 13:59
|
15. nov 2011
replaced IVC converter units for B0 ans B1 of 0X.
also replaced B2.
Juergen |
|
(0000368)
Juergen Morawietz
15-12-11 13:41
|
15.12.2011
Status => closed