| ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
| 0000380 | [DZB] correlator board | major | always | 28-09-11 11:43 | 05-10-11 12:07 | ||||
| Reporter | Yuan Tang | View Status | public | ||||||
| Assigned To | Sjouke Zwier | ||||||||
| Priority | normal | Resolution | fixed | ||||||
| Status | resolved | ||||||||
| Summary | 0000380: There is the problem on the correlator | ||||||||
| Description |
There is still the correlator problem which causes the different problem with different settings: In settings of 8 bands,4 polars,128ch,BW=10MHz(recirculation factor 2): The cross correlations of 0-7YDY have no Ampls in band2,6. In settings of 8 bands,2 polars,256ch,BW=10MHz(recirculation factor 2): All cross correlations of *XDX,*YDY have no Ampls in band5 and no TPs of DX,DY in band5. In settings of 8 bands,4 polars,64ch,BW=20MHz: All cross correlations of *YDY have no Ampls in band5 and no TP of DY in band5. (Sjouke and Albert: Above informations may be helpful for you to locate the problem in the correlator. For 4 polars data only know the problem on XX,YY but not on XY,YX.) |
||||||||
| Additional Information | |||||||||
| nr subbands | 1 | ||||||||
| nr polarisations | |||||||||
| nr channels | |||||||||
| bandwidth | |||||||||
| multi-subarray | no | ||||||||
| recirculation | yes | ||||||||