0000302 | [VLBI] 0.unknown/unspecified | major | always | 08-11-10 12:28 | 11-11-10 11:58 | ||||
Reporter | Geert Kuper | View Status | public | ||||||
Assigned To | Pieter Donker | ||||||||
Priority | high | Resolution | fixed | ||||||
Status | resolved | ||||||||
Summary | 0000302: The telephone alarm for observer bedroom does not work. | ||||||||
Description |
The telephone alarm mode of CtrlAlarmmodem does not work. Probably due to a bad or broken line. |
||||||||
Additional Information | |||||||||
Attached Files | |||||||||
|
Notes | |
(0000308) Geert Kuper 11-11-10 10:46 |
The HF connector filters were damaged, probably by the lightning strike of summer 2010. Pieter Donker changed to another connector and the problem was gone. |