Anonymous | Login | 23-11-2024 17:52 UTC |
All Projects | CNI | DZB | equalizer | IVC/ADC | LFFE | MFFE | Puma | Puma 2 | RFI | RT | submission | system time | Tadu | Time/LO | TMS | VLBI |
Main | My View | View Issues | Change Log | Docs |
Viewing Issue Simple Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
0000189 | [TMS] | minor | always | 25-11-09 15:21 | 14-06-10 07:55 | ||||
Reporter | Arno Schoenmakers | View Status | public | ||||||
Assigned To | Arno Schoenmakers | ||||||||
Priority | normal | Resolution | fixed | ||||||
Status | closed | ||||||||
Summary | 0000189: FillArchive does not always archive all MSes which causes alarms | ||||||||
Description |
When, for some reason, many empty or small MSes (timeframes) are produced in an observation (e.g., ReadDZB crash), the Fillarchive process does not copy all MSes to the archive. This in turn will cause checkArchive to raise a daily alarm through the warn as there are inconsistencies between the wop29 and the archive. FillArchive currently checks only the last 20 MSes; this must be changed so that it checks the last x measurements. |
||||||||
Additional Information | |||||||||
Attached Files | |||||||||
|
Notes | |
(0000241) Arno Schoenmakers 03-02-10 15:32 |
FillArchive now look back 20 sequencenumbers, instead of only 20 MSes. Deployed on 2010-02-03. |