0000186: The TP of BX is unstable at Lband(problem from jumper?).

  

Viewing Issue Simple Details Jump to Notes ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000186 [RT] 0.unknown/unspecified minor always 16-11-09 10:39 17-01-11 17:24
Reporter Yuan Tang View Status public  
Assigned To Harm-Jan Stiepel
Priority normal Resolution fixed  
Status closed  
Summary 0000186: The TP of BX is unstable at Lband(problem from jumper?).
Description The TP of BX(MFFE-09) is unstable at Lband.
(The problem seems from the MFFE-09 after comparing with the TP from the MFFE-09.)
Additional Information 20100228:
After the MFFE having been replaced on RTB, the TP of BX/MFFE-10
  is still unstable which happened at the beginning part of 12h observation
  (see 11001128).
  (The problem might come from the cable, the cable of the jumper?)
RT B
Attached Files

- Relationships

- Notes
(0000277)
Harm-Jan Stiepel
26-03-10 14:44

Op 3 maart is de poolasjumper vervangen.
 

- Issue History
Date Modified Username Field Change
16-11-09 10:39 Yuan Tang New Issue
16-11-09 10:39 Yuan Tang MFFE  => 09
16-11-09 10:39 Yuan Tang RT  => B
16-11-09 10:39 Yuan Tang MFFE-band  => L-band
16-11-09 10:39 Yuan Tang polarisation  => X
16-11-09 10:40 Yuan Tang Assigned To  => Harm-Jan Stiepel
16-11-09 10:40 Yuan Tang Status new => assigned
28-02-10 10:46 Yuan Tang Summary The TP of BX(MFFE-09) is unstable at Lband. => The TP of BX is unstable at Lband(problem from jumper?).
28-02-10 10:46 Yuan Tang Additional Information Updated
01-03-10 09:38 Harm Munk Project MFFE => RT
26-03-10 14:44 Harm-Jan Stiepel Note Added: 0000277
26-03-10 14:44 Harm-Jan Stiepel Status assigned => testing
26-03-10 15:12 Harm-Jan Stiepel Resolution open => fixed
17-01-11 17:24 Harm Munk Status testing => resolved
17-01-11 17:24 Harm Munk Status resolved => closed